FLU COV Ag OG (2)

Influenza A – Influenza B & Antigen COVID-19 Combo Rapid Test Cassette (Swab)

FLU COV Ag OG (2)

 

The Influenza & COVID-19 Ag Combo Rapid Test Cassette (Swab) is an in vitro immunochromatographic assay for the qualitative and differential detection of nucleocapsid  protein antigen from Influenza A (including the sub-type H1N1) and Influenza B and/or SARS-CoV-2 in nasopharyngeal (NP) swab specimens .

For further information please write to  info@futurasystem.it.

test-rapidi

Card: introduced new rapid test and positive controls

test-rapidi

 

FSG introduced new packaging and new rapid tests for the screening of several disease: infectivity (Rota-Adeno Virus, Clostridium Difficile GDH and Toxin A-B, Streptococcus Pneumoniae, Legionella Pneumophila, etc), cardiac markers (Troponin I) and qualitative detection of protein (Calprotectin).

For such tests are available positive controls.

For any further information visit the web site, section PRODUCTS - RAPID TEST.

dsc_0517

New liquid coagulation line

dsc_0517

 

 

The new CH Coagulation line  includes liquid and ready to use Thromboplastin, three different types of Clauss Fibrinogen suitable on different coagulometers, PT and Fibrinogen calibrators, normal and pathologic controls  with values referred to a large number of instruments:

  1. CH111: Thromboplastin stable  60 days at 2-8°C, liquid and ready to use. There are no possibilities of handling/reconstitution errors through pipetting or water quality, our liquid reagent is less turbid, it gives more consistent results between analysers and there is no settling across short periods of time on board therefore it is able to work on analysers without a stir bar. Assigned value for Coatron A4, Sysmex, ACL, CoaData, Labitec, Behnk, etc
  2. CH224: APTT SI + Calcium Cloride (Silicate Activator) stable 30 days at 2-8°C
  3. CH100A: Clauss Fibrinogen 100 NIH/ml: lyophilized thrombin and imidazole buffer. Dedicated calibrator and caolin are separately supplied
  4. CH050A: Clauss Fibrinogen 50 NIH/ml: lyophilized thrombin, imidazole buffer and dedicated calibrator
  5. CH035A: Clauss Fibrinogen 35 NIH/ml: lyophilized thrombin, imidazole buffer and dedicated calibrator
  6. CH008: Caolin dedicated for Fibrinogen 100 NIH/ml on manual instruments
  7. CH020: Calibrator dedicated for Fibrinogen 100 NIH/ml
  8. CH021: PT calibration curve: 4 activity levels (%) for PT
  9. CH022: Coagulation Calibrator that includes Coagulation factors, PT on specific coagulometers, Fibrinogen 100, C and S Protein, Antithrombin, etc
  10. CH004-CH005: Normal and pathologic Controls with values referred to a large number of coagulometers (Coatron A4, Sysmex, ACL, CoaData, Labitec, Behnk, etc)

For further information, visit our web site www.futurasystem.it and download the documents  or contact us via mail at  info@futurasystem.it

Hitachi

Instrument applications

FSG gives to the customers a large number of tested applications or line guide on the most common instruments on the market such as Hitachi 911-912-917, Biolis 50, Biolis 24i, Biolis 30i, Cobas Mira, Konelab, Mindray, Targa BT Plus, Olympus AU400, etc. Require the Master sheet Application to have immediately an idea of the available applications. FSG technical assistance will provide support for the applications not available in the list.

biolis-30

New Clinical Chemistry Analyzer from Tokyo Boeki: Biolis 30i

Biolis 30i is the latest automated analyzer for Chemical Chemistry  model of  Biolis series. It is a fully automated, bench-top use clinical analyser developed and manufactured in Japan.

New functions has been developed as Sample clot detection, Crash prevention. The reagent tray is the same of Biolis 24i and so also the reagent bottles. Futura System Group s.r.l. has certified all its reagents line on the instrument.

25

Serology: expanded catalogue with Proteus screening

25

 

Futura System Group expanded its Serology’s catalogue completing the WW series of the coloured inactive bacterial suspension (1x20 ml) for the quantitative determination of the antibodies by agglutination in tube test, including the complete Proteus panel (Proteus OX2 - Proteus OX19 - Proteus OXK) to the already affirmed Brucella and Salmonella screening; introducing the WF series, a new type of rapid test containing a coloured inactive bacterial suspension  for the qualitative determination of the antibodies by agglutination on slide and the semi-quantitative determination on microplates, including the complete Brucella, Salmonella and Proteus panel (Proteus OX2 - Proteus OX19 - Proteus OXK);.       introducing positive and negative controls for Brucella, Salmonella and Proteus useful for Quality Control These products have different method and different incubation time, as explained here below:

WW SERIES (1X20ml) – Bacterial Suspensions for TUBE Tests 40 TESTS (500 µl/test) 16-18h at 37°C                                                                                                                                                  

WF SERIES (1X5ml) – Bacterial Suspensions for SLIDE  100 TESTS (50µl/test) and MICROPLATE 500 Tests (10 µl/test) 24h a 37°C o 4h a 52°C   For further information, please see the catalogue on line.